Nonwoven Liquid Penetration Tester STD-MB03B

Test PrincipleA solution of known volume (e.g., artificial urine with a surface tension of 70dy

Aplikasi WhatsApp: +86 13816217984

Email :info@qinsun-lab.com

Konten

Prinsip Ujian

A solution of known volume (e.g., artificial urine with a surface tension of 70dyn/cm) is placed in a teflon-lined container.A solenoid valve is used to drain the liquid at a constant rate through the center hole of the nonwoven upper plate (through the electrode plate).The two electrodes start the timer with a conductive liquid.The nonwoven sample is placed on a set of 5/10 pieces of filter paper that ACTS as a suction liquid.When all the conductive liquid enters the suction layer, the circuit current will interrupt and stop the timer.EDANA requires the configuration of artificial urine at a rate of 25ml/3.5±0.25s.

Standard

GB/T 24218.14. FZ/T 60017. GB/T 24218.8.EDANA

Ciri-ciri

1. High precision peristaltic pump ensures the accuracy of liquid penetrating capacity.

2. Automatic refueling function, automatic testing throughout the process, no need for manual refueling.

3. The penetrating disc is made of special plexiglass and is guaranteed to be 500 grams ±5 grams after special processing.

4. Automatically save data after completing the test, and check the calculation and analysis results of the report, and print the test report.

5. Touch screen control panel and clear image interface provide more convenient and quick operation for testers.

6. Free access to all data and statistical results in the host.

7. The penetrating disc is equipped with precise positioning device to avoid collision damage.

8. Platinum wire electrode is used for penetrating disc electrode, which is sensitive, precise and durable.

9. Instrument liquid release is equipped with automatic release device, which can realize automatic control and stable flow rate.

Key Specification

 
ModelSTD-MBO3B
Automatic liquid dosageCan be set from 0.1 to 10.0ml (Settable
Test accuracy0.01s
penetration times1-5 times can be set
Interval time20-99s is adjustable
Size of penetrating disc100x100x25 mm
Total mass of penetrating disc500g+59
The time of Battery valve's funnel flow rate 25ml3.5s+0.3s
Pasukan listrikAC 220V 50Hz 100W
Extemal dimension400x375x520mm
ConnectionOptional USB communication, connect to the computer
 

Penafian: Konten di atas hanya untuk referensi dan komunikasi antara orang dalam industri, dan tidak menjamin akurasi atau kelengkapannya. Menurut hukum dan peraturan yang relevan dan peraturan situs web ini, unit atau individu yang membeli barang terkait harus memperoleh kualifikasi dan kondisi kualifikasi yang valid.