Tests vehicle cabin air filters for particulate filtration efficiency and pressure drop.
WhatsApp: +86 13816217984
Email: info@qinsun-lab.com
Applicable standards:
DIN 71460-1 Road vehicles - Air filters for passenger compartments of motor vehicles - Part 1: particulate matter filtration tests
SO/TS 11155-1 Road vehicles - Air filters for occupants' compartments - Part 1: particulate filtration test.
Product Advantages:
Complies with recognized international standards like DIN 71460-1 and ISO/TS 11155-1. ensuring standardized and comparable test results.
Accurately measures particulate matter filtration efficiency across a wide range of particle sizes.
Enables precise determination of pressure drop and dust loading capacity, critical performance indicators.
Equipped with highly accurate sensors for real-time monitoring of temperature, relative humidity, and atmospheric pressure.
Utilizes advanced components for precise dust dispersion (e.g., SAG 410/L), aerosol generation (e.g., ATM 220), and electrostatic neutralization (e.g., EAN 581).
Features high-precision particle counters (e.g., TOPAS spectrometer LAP321) for accurate particle measurement.
Facilitates comprehensive and repeatable testing essential for product development, validation, and quality assurance.
Product Features:
Air Flow System: Capable of generating and controlling airflow rates from 70 to 700 m³/h.
Pressure Difference Measurement: Integrated sensors and system for measuring pressure drop across the filter from 0 to 1000 Pa.
Filter Adapter: Designed to securely mount and test filters with dimensions up to 300 x 600 mm.
Test Section: Standardized cross-section of 180 cm² for consistent airflow distribution.
Environmental Sensors: Integrated sensors for continuous monitoring of temperature, relative humidity, and atmospheric pressure during tests.
Dust Disperser: Specific model SAG 410/L, capable of dispersing dust from 2 to 245 g/h.
Aerosol Generator: Specific model ATM 220 for generating test aerosols.
Electrostatic Neutralizer: Specific model EAN 581 for neutralizing electrostatic charges on aerosols.
Light Particles / Particle Counter: Utilizes laser aerosols in conjunction with a TOPAS spectrometer LAP321 for accurate particle counting and sizing.
Control and Data Acquisition System: (Implied) for automated test sequences, data logging, and analysis.
Technical parameters:
Air flow :70… 700 m3/h
Pressure difference :0… 1000 Pa?
Filter adapter :300x600 mm
Cross section :180 cm2
Sensors: temperature, relative humidity, atmospheric pressure
Dust disperser :SAG° 410/L(2… 245 g/h)
Aerosol generator :ATM 220
Electrostatic neutralizer :EAN 581
Light particles: laser aerosols
Counter :TOPAS spectrometer LAP321
Power Supply :400 V AC, 16 A
Test bench size :460x120x340cm
Penafian: Konten di atas hanya untuk referensi dan komunikasi antara orang dalam industri, dan tidak menjamin akurasi atau kelengkapannya. Menurut hukum dan peraturan yang relevan dan peraturan situs web ini, unit atau individu yang membeli barang terkait harus memperoleh kualifikasi dan kondisi kualifikasi yang valid.