Main PurposeIt is mainly used for the extremely high - temperature pre - treatment of safety helmets
Email: info@standard-groups.com
Main Purpose
It is mainly used for the extremely high - temperature pre - treatment of safety helmets.
Compliance Standard
GB/T2812-2019
Parameter Teknik
1. Test chamber temperature: Room temperature - 200°C, with the standard operating temperature being 150±5°C. 2. Test time: 0 - 99 minutes, adjustable, with the standard being 60±2 minutes. 3. Number of test samples: 1 - 4 helmets. 4. Head mold temperature: 50°C±2°C. 5. Test head mold: Wall thickness > 1.5mm, size according to No.1 in GB2812, made of aluminum alloy with a hollow interior. 6. Temperature - measuring point of the head mold: The distance from the mid - point of the head mold is < 40mm. 7. Instrument dimensions: 870*710*1100mm
Penafian: Konten di atas hanya untuk referensi dan komunikasi antara orang dalam industri, dan tidak menjamin akurasi atau kelengkapannya. Menurut hukum dan peraturan yang relevan dan peraturan situs web ini, unit atau individu yang membeli barang terkait harus memperoleh kualifikasi dan kondisi kualifikasi yang valid.
Telepon Perusahaan
+86-21-6420 0566
Jam kerja
Senin sampai Jumat
Telepon seluler:
13816217984
Email:
info@qinsun-lab.com