I. Product Overview
The High Temperature Oxygen Index Tester is an advanced combustion testing instrument designed to determine the minimum oxygen concentration required to sustain flame propagation in materials under elevated temperature conditions. It evaluates thermal stability and flame retardancy properties, critical for aerospace, automotive, and industrial material development.
- Type: High-temperature oxygen index (OI) analyzer
- Test Method: ASTM D2863 (Oxygen Index) with elevated temperature capability
- Temperature Range: Ambient +20°C to 400°C (±1°C accuracy)
- Key Metrics:
- Oxygen Index (OI) at 23°C and elevated temperatures
- Flame Spread Rate (cm/s)
- Time-to-Ignition (TTI, seconds)
- Sample Size: 100×100×3mm (adjustable clamping)
II. Technical Specifications
Parameter |
Specifications |
Oxygen/Nitrogen Control |
0–100% O₂ (programmable, 0.1% resolution) |
Heating Rate |
10°C/min (max, PID-controlled) |
Gas Flow Rate |
0.1–5 L/min (mass flow controllers) |
Flame Stability |
±0.5mm flame height (auto-adjusting burner) |
Power Supply |
380V/50Hz, 3kW (heating elements) |
Dimensi |
1200×800×1600mm (L×W×H) |
III. Key Features
- Dual-Environment Testing:
- Standard Mode: Ambient temperature OI measurement
- High-Temp Mode: Simulates thermal degradation (up to 400°C)
- Advanced Combustion Analysis:
- Real-time OI curve plotting
- AI-based flame behavior prediction
- Video recording with flame front tracking
- Automation:
- Motorized oxygen/nitrogen valve control
- Programmable thermal cycling
- Self-cleaning exhaust system
IV. Compliance Standards
- ASTM D2863 (Oxygen index of plastics)
- ISO 4589-2 (Plastics—Determination of burning behavior)
- NFPA 701 (Flammability of textiles)
- GB/T 2406.2 (Chinese oxygen index standard)
V. Applications
- Aerospace: Evaluating thermal protection systems
- Automotive: Testing interior material flammability
- Fire Safety: Certifying flame-retardant coatings
- R&D: Developing high-temperature composites
Standard Operation Workflow:
- Sample Preparation: Cut to size, clamp vertically
- Parameter Setup: Select temperature (e.g., 200°C) and O₂ range
- Testing: Ignite burner and adjust gas flow
- Analysis: Calculate OI at target temperature
- Cleaning: Automated soot extraction
Safety Precautions:
- Heat-resistant gloves required for sample handling
- Gas leak detectors mandatory
- Maintain 1m clearance from exhaust vents

Penafian: Konten di atas hanya untuk referensi dan komunikasi antara orang dalam industri, dan tidak menjamin akurasi atau kelengkapannya. Menurut hukum dan peraturan yang relevan dan peraturan situs web ini, unit atau individu yang membeli barang terkait harus memperoleh kualifikasi dan kondisi kualifikasi yang valid.